Products / Carbon & Alloy Steel

SA213 T2, the entry-level chrome-moly boiler tube.

Half a percent each of chromium and molybdenum gives T2 better creep strength than carbon steel at a small premium. It is the first step up from SA179 or SA192 when tube-wall temperatures start to climb.

AlloySA213 T2 Alloy Steel Boiler Tube
FamilyCarbon & Alloy Steel
Supplied toASME SA213 T2, ASTM A213 T2
Typical serviceBoilers, Superheaters
Size range1/2" to 3" OD, .065" to .220" wall, cut lengths and random lengths
TempersNormalized, or normalized and tempered per SA213
Testing100% NDE (eddy current or ultrasonic) per SA213, hydrostatic on request, hardness, flattening, flaring
OriginDomestic and approved import mills, inspected and certified in Hillsboro
Sourced alloy, certified in HillsboroAmeritube does not manufacture SA213 T2 in Texas. It is supplied from qualified domestic and international mills, then received, inspected, tested, and released under our ISO 9001:2015 system in Hillsboro, Texas, with a full mill test report.

What SA213 T2 is

ASME SA213 covers seamless ferritic and austenitic alloy steel tube for boilers, superheaters, and heat exchangers. Grade T2 is a low-alloy ferritic steel with nominally 0.5% chromium and 0.5% molybdenum. The molybdenum raises high-temperature strength and the chromium adds oxidation resistance, extending service beyond the limits of plain carbon tube.

Chemical composition

Element Requirement
Carbon 0.10 to 0.20%
Manganese 0.30 to 0.61%
Silicon 0.10 to 0.30%
Chromium 0.50 to 0.81%
Molybdenum 0.44 to 0.65%
Phosphorus / Sulfur 0.025% max each

Mechanical properties

Property Minimum
Tensile strength 60,000 psi (415 MPa)
Yield strength 30,000 psi (205 MPa)
Elongation in 2" 30%
Hardness 85 HRB max

Where it is used

Economizers, low-temperature superheater sections, waterwall tube, and heat exchangers running warmer than carbon steel likes. Common in industrial boilers, HRSGs, and refinery process heaters.

Where it stops

Above roughly 950 to 1000 degrees F metal temperature, move to T11, T12, or T22. We stock and source the whole SA213 ferritic range, so a mixed-grade boiler retube can come from one order.

What to put in your SA213 T2 RFQ

OD, minimum wall, length, quantity, heat treatment condition, any supplementary requirements (S1 through S8 in SA213), and whether the tube is for a Section I boiler or a Section VIII exchanger.

Documents

Related alloys

Industries