The challenge
- Long-length SA179 tubing, over 60 feet straight before bending.
- Complex U-bend geometry in large bundle assemblies.
- Multi-stage qualification and coordination between the customer, the exchanger fabricator, and suppliers.
- Schedule-sensitive delivery and customer-ready documentation.
How the project ran
- Technical review and quote development.
- Supplier qualification and sourcing.
- Procurement and production planning.
- Material certification review.
- 100% eddy current and dimensional verification on the straight tubes.
- U-bending, stress relief of the bends per customer specification, and bend verification.
- Packaging and logistics coordination.
- Final delivery of completed bundles.
Quality documentation
Product test report confirming material compliance, eddy current test report, dimensional inspection report, bending inspection and bend geometry report, all organised into one package for customer release.
The result
A 9-month program completed, ready-for-installation bundle components delivered, and a demonstrated capability in large heat exchanger bundle work.